AT9636 Electrical safety analyzer is an instrument that integrates multiple testing functions of electrical strength (AC/DC withstand voltage) and insulation resistance, rate output 5kV/100mA, 500VA. It is an important testing equipment for electrical manufacturers
and quality inspection departments.
Adopt a high-speed microprocessor as the control core, which can measure various safety parameters of the tested object in real time, and complete three tests within 4 seconds, which especially can meet the rapid testing requirements of the production line.
Adopt a 9-inch color LCD screen display, which can quickly complete various settings and tests by numeric keyboards, simple to operate; the large screen display can display more detailed test information and data on one page.
Intelligent judgment function of upper and lower limits, can automatically identify defective products, and provide sound and light alarms.
Adopts a variety of anti-interference measures with strong anti-interference ability.
High- voltage non-contact adjustment.
It has hardware and software protection, which greatly improves the reliability of the instrument.
Automatic over-voltage and over-current protection makes it safer to use.
Measurement Functions | AC/DC Withstanding Voltage & Insulation Resistance(IR) |
Interface | RS232,HANDLER,ALARM,REMOTE,USB-232/RS485(Options) |
Standard Configuration | 5kV,100mA,500VA |
Comparator | UPPER/LOWER |
Protect Function | OV/OC |
Other Functions | LIST Edit |
Discharge Function | |
9 inch LCD + Touch panel | |
AC Withstand Voltage | |
Rate Ouput | AC 5.000kV/100mA |
Output Power | 500VA (≥90%) |
Output Voltage | 100~5000 V AC; Resolution: 1V |
Voltage Accuracy | 2% of reading + 5 digits |
Output Regulation | 2% of reading +5V |
Voltage Output Stability | ±(0.4% of setting +1V)/ min,From no load to full load |
Output Ripple | Resistive Load:<2% |
Output Frequency | 50Hz/60Hz |
Short-circuit Current | >200mA |
Voltage Measurement | (0.10 ~ 5.00)kV,Resolution:0.01kV |
Voltage Accuracy | (1.5% of reading+1 counts) |
Measurement Current | 0.000~3.500/3.00~100.00 mA , Resolution:0.001/0.01 mA |
Current Accuracy | 2% of reading + 5 digits |
DC Withstand Voltage | |
Rate Output | DC 6kV/10mA |
Output Power | 60VA, ≥90% |
Output Voltage | 0.1kV-6.000kV DC; Resolution: 1V |
Voltage Accuracy | 2% of reading + 5 digits |
Output Regulation | ±(2% of setting +5V),From no load to full load |
Output Ripple | <5%(6kV/1mA at Resistive Load) |
Current Measurement | 0.0~350.0/300~3500/3000~9999 μA/10mA |
Resolution: 0.1/1/10μA/0.01mA | |
Current Accuracy | 2% of reading +5 Counts |
Insulation Resistance | |
Rate Output | DC 2.5kV/9999MΩ |
Output Voltage | 100~2500V DC; Resolution: 1V |
Voltage Accuracy | 2%of setting +5V |
Drop Voltage | Not less than rated voltage 90%,drop resistance 10MΩ(1% of range) |
Measurement Range | 0.1MΩ-10GΩ |
IR Accuracy | Range:(1 ~9999) MΩ,Resolution: 1MΩ |
Accuracy:(100-499) V, 1~1000,±(8% of reading +2counts) | |
1000~2000,±(12% of reading + 2counts) | |
(500-2500V),1~199,±(2% of reading + 2counts), | |
200~999, ± (5% of reading + 2counts) | |
1000~9999, ± (15% of reading + 2 counts) | |
Power Supply | 198V~242V AC;50/60Hz |
Dimension | 400mm(W)*200mm(H)*503.5mm(D) |
Weight | 20kg |