  • Comprehensive combine 8 functional test hipot tester

    Model: AT9005

    Features:   

    ●AC/DC withstand voltage, Insulation, Ground impedance, Leak current, AC/DC power, Comprehensive combine 8 functional test
    ●Equipped with PLC interface,Variable frequency power supply control interface, communication interface, etc.
    ●1.5 level safety test accuracy
    ●0.5 level electrical parameter test accuracy
    ●Possess a unique self-check function to simplify production operations
    ●Sound and light alarm

  • Products You May Like
    • Overview
    • Specification
    • Send your inquiry
    • AT9005 Comprehensive safety tester is a multi-function meter with great performance and high reliability electrical safety tester. can realize AC/DC withstand voltage, insulation, ground impedance, leak current, AC/DC power, comprehensive etc eight test function. 2% test accuracy, Multiple measurement parameters are displayed simultaneously, system adopt ARM processor, 9 inch TFT LCD display, can complete the parameters measurement fast and accuracy, Handler, RS232 etc interface which can meet the test requirfements of different user. AT9005 can offer safety test solution for electric car, power grid,photovoltaic, home appliances, information equipment,medical equipment industry and offer innovative solutions for all kinds of electrical measurements.


    • Measurement FunctionsAC/DC Withstand Voltage, Insulation Resistance, Grounding,leakage, AC/DC Power
      InterfaceUSB-HOST, RS232/RS485, HANDLER, ALARM, REMOTE
      Protect FunctionOV/OC
      Other Functions9 inch LCD
      AC Withstand Voltage
      Rate Ouput5kV   AC,40mA
      Output Power200VA
      Output Voltage100 ~ 5000 V AC Resolution:resolution   1V
      Voltage Accuracy2%× Reading + 5Digits
      Output Frequency50Hz   / 60Hz,Accuracy: ±0.1Hz
      Measurement Current0.005-9.999mA-20.00mA;   Resolution:0.001mA/0.01mA
      Current Accuracy2% × Reading + 5Digits
      Rising Time0.1s-999.9s
      Testing Time0.5s-999.9s
      Falling Time0.1s-999.9s
      DC Withstand Voltage
      Rate Output6kVdc/10mA
      Output Power120VA
      Output Voltage100~6kV DC ; Resolution: 1V
      Voltage Accuracy2% × Reading + 5Digits
      Output Regulation<2%
      Rising Time0.1s-999.9s
      Testing Time0.5s-999.9s
      Falling Time0.1s-999.9s
      Insulation Resistance
      Rate Output1kV/3GΩ
      Output Voltage100~1000V   ; Resolution:1V
      Voltage Accuracy2%   × Reading + 5Digits
      Measurement Range0.1MΩ-3 GΩ
      IR Accuracy<500V:
      0.1MΩ-100 MΩ: 5%×Reading+5Digits
      100MΩ-1 GΩ : 10%×Reading+5Digits
      ≥500V:
      0.1MΩ-100 MΩ: 2%×Reading+5Digits
      100MΩ-2 GΩ: 5%×Reading+5Digits
      2 GΩ-3 GΩ: 10%×Reading+5Digits
      Testing Time0.5s-999.9s
      Ground Impedance
      Rate Output30A, 600mΩ
      Output Current30A
      Output Voltage<12V
      Frequency50Hz / 60Hz,Accuracy:±0.1Hz
      Testing Time0.5s-999.9s
      Leak Current
      Test Voltage OutputSingle-phase,   requires external isolation transformer or variable frequency power supply to   provide voltage and frequency required for testing
      Test TypeG-L,G-N,AUTO(G-L,G-N)
      AC Voltage MeasurementRange:5.0-300.0V   ; Resolution:0.1V; Accuracy: ±(1.5%×Reading+3V)
      AC Current MeasurementRange:0.000-9.999-20.00mA
      Resolution:0.001mA/0.01mA
      Accuracy: 0.005-9.999mA ±(1.5%×Reading+0.005mA)
      10.00-20.00mA ±(1.5%×Reading+0.05mA)
      Testing Time0.1s-999.9s
      AC Power
      AC Voltage Output

      Single-phase, requires external isolation transformer or variable frequency power supply to

      provide voltage and frequency required for testing

      AC Voltage MeasurementRange:0.0-300.0V;   Resolution: 0.1V; Accuracy: ±(0.25%×Reading+0.25%×Range)
      AC Current MeasurementRange:0.000-9.999-25.00A ; Resolution:0.001A/0.01A; Accuracy: ±(0.25%×Reading+0.25×Range)
      Power MeasurementRange:5.0-999.9-6000W; Resolution:0.1W/1W; Accuracy: ±(0.25%×Reading+0.25×Range)
      Power FactorRange:-1.00 – 1.000; Resolution:0.001; Accuracy: ±(0.5%×Reading+0.01)
      Testing Time0.1s-999.9s
      DC Power
      DC Voltage OutputNeed external DC power supply to provide voltage and frequency required for testing
      DC Voltage MeasurementRange:0.0-300.0V;   Resolution: 0.1V; Accuracy: ±(0.25%×Reading+0.25%×Range)
      DC Current MeasurementRange:0.000-9.999-25.00A;   Resolution:0.001A/0.01A; Accuracy: ±(0.25%×Reading+0.25×Range)
      Power MeasurementRange:5.0-999.9-6000W;Resolution:0.1W/1W ; Accuracy: ±(0.25%×Reading+0.25×Range)
      Testing Time0.1s-999.9s
      Power Supply198V~242V AC; 50Hz/60Hz; 300VA
      Dimension400mm* 200mm*503.5mm
      Weight30kg
    • *From: