Specifications | ||||
Input Rating | Power | 6000W | ||
Current | 0-120A | |||
Voltage | 0-500V | |||
CC Mode | Range | 0-12A | 0-120A | |
Resolution | 1mA | 10mA | ||
Accuracy | 0.05%+0.05%FS | 0.1%+0.05%FS | ||
CV Mode | Range | 0.1-19.999V | 0.1-500V | |
Resolution | 1mV | 10mV | ||
Accuracy | 0.03%+0.02%FS | 0.03%+0.05%FS | ||
CR Mode | Range | 0.3Ω~2K | 0.3Ω~5K | |
Resolution | 16 bit | 16 bit | ||
Accuracy | 0.1%+0.1%FS | 0.1%+0.2%FS | ||
CW Mode | Range | 0-6000W | 0-6000W | |
Resolution | 1mW | 10mW | ||
Accuracy | 0.1%+0.1%FS | 0.1%+0.2%FS | ||
V Measurement | Voltage | 0-19.999V | 0-500V | |
Resolution | 1mV | 10mV | ||
Accuracy | 0.015%+0.03%FS | 0.015%+0.05%FS | ||
I Measurement | Current | 0-12A | 0-120A | |
Resolution | 0.1mA | 1mA | ||
Accuracy | 0.1%+0.1%FS | 0.1%+0.25%FS | ||
W Measurement | Watt | 100W | 6000W | |
Resolution | 1mW | 10mW | ||
Accuracy | 0.1%+0.1%FS | 0.1%+0.2%FS | ||
Battery Measurement | Battery Input:0.5-120V;Max.Measurement:Capacity=999/H; Resolution=0.1mA;Time Range=1S-16HS | |||
Dynamic Measurement | Transition List:0-25kHz; 5A/uS;T1& T2:60uS-999S;Accuracy:±15% offset+10% FS | |||
CC soft-startup Time | 1mS; 2mS;5mS;10mS; 20mS; 50mS;100mS; 200mS Accuracy: ± 15% offset+10% FS | |||
Short Circuit | Current(CC) | 26.4A | 26.4A | |
Voltage(CV) | 0V | |||
Resistance(CR) | 7mΩ | |||
Temperature | Operating | 0~40°C | ||
Nonoperating | –10°C~70°C | |||
Dimension | W*H*D(mm) | 575*465*355 | ||
Weight | Kg | 70 | ||