Products    >    Handheld Oscilloscopes  >    Hantek Oscilloscope  >    DSO8102E
  • 100MHz Handheld Scopemeter

    Model: DSO8102E

    Features:   

    ●5.6 inch TFT LCD display

    ●2 Channel with 2M record length

    ●100MHz bandwidth with 1GS/s real time sampling rate

    ●Build-in 25MHz Signal Generator

    ●Six in one: Oscilloscope/Recorder/6000 dots DMM/Signal generator/FFT 

    ●Spectrum Analyzer/Frequency Counter

    ●Waveform data can be output in WORD,EXCEL, BMP, JPG 

    ●Interface:USB_Host,USB_Device,WIFI/LAN(Optional)

  • Products You May Like
    • Overview
    • Specification
    • Compare
    • Download
    • Send your inquiry
    • Model

      DSO8072E

      DSO8102E

      DSO8152E

      DSO8202E

      Sample Modes

      Real-Time Sample

      Normal

      Normal data only

      Peak Detect

      High-frequency and randon glith capture

      Average

      Wavefom Average, selectable 4,8,16,32,64,128

      Inputs Coupling

      AC, DC, GND

      Inputs Impendance

      1MΩ±2% ‖20pF±3pF

      Probe Attenuation

      1X, 10X

      Supported Probe Attenuation Factor

      1X, 10X, 100X, 1000X

      Maximum Input Voltage

      CAT I and CAT II: 300VRMS (10×), Installation Category; CAT III: 150VRMS   (1×)

      Horizontal System

      Sample Rate Range

      1GS/s

      Waveform Interpolation

      (sin x)/x

      Record Length

      2M

      SEC/DIV Range

      4ns/div~2000s/div, in a  2, 4, 8 sequence

      2ns/div~2000s/div, in a  2, 4, 8 sequence

      Sample Rate and Delay Time Accuracy

      ±50ppm over any ≥1ms time interval

      Scanning Speed    Range

      4ns/div to 8ns/div; (-8div x s/div) to 40ms;
        20ns/div to 80μs/div;(-8div×s/div) to 40ms
        200μs/div to 40s/div; (-8div×s/div) to 400s

      2ns/div to10ns/div;
         (-4div×s/div) to 20ms;

      Delta Time Measurement Accuracy 
        (Full Bandwidth)

      Single-shot, Normal mode:± (1 sample   interval +100ppm × reading + 0.6ns);
        >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);Sample   interval = s/div ÷ 200

      Vertical System

      Vertical Resolution

      8-bit resolution, all channel sampled simultaneously

      Volts Range

      2mV/div to 100V/div at input BNC

      Bandwidth

      70MHz

      100MHz

      150MHz

      200MHz

      Rise Time at BNC( typical)

      5ns

      3.5ns

      2.3ns

      1.8ns

      Analog Bandwidth in Normal   and 

      Average modes at BNC or with p

      robe, DC Coupled

      ±400V(100V/div-20V/div);  ±50V(10V/div-5V/div);   ±40V(2V/div-500mV/div); 
        ±2V(200mV/div-50mV/div); ±400mV(20mV/div-2mV/div)

      Math

      +, -, *, /, FFT

      FFT

      Windows:Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample   point

      Bandwidth Limit

      20MHz

      Low Frequency Response (-3db)

      ≤10Hz at BNC

      Trigger System

      Trigger Types

      Edge, Video, Pulse, Slope, Over time, Alternative

      Trigger Source

      CH1, CH2, AC Line

      Trigger Modes

      Auto, Normal,   Single

      Coupling Type

      DC, AC, HF Reject, LF Reject, Noise Reject

      Trigger Sensitivity

      DC(CH1,CH2): AC; HF Reject; LF Reject

      Trigger Level Range

      CH1/CH2: ±8 divisions from center of screen; 

      Video Trigger

      Video Trigger Type

      CH1, CH2: Peak-to-peak amplitude of 2 divisions;

      Signal Formats and Field Rates

      Supports NTSC, PAL and SECAM broadcast systems for any field or any line

      Holdoff Range

      100ns ~ 10s

      Pulse Width Trigger

      Pulse Width Trigger Mode

      Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse

      Pulse Width Trigger Point

      Equal: The oscilloscope triggers when the trailing edge of the pulse   crosses the trigger level.

      Not Equal: If the pulse is narrower than the specified width, the   trigger point is the trailing edge. Otherwise, the oscilloscope triggers when   a pulse continues longer than the time specified as the Pulse Width.

      Less than: The trigger point is the trailing edge.

      Greater than (also called overtime trigger): The oscilloscope triggers   when a pulse continues longer than the time specified as the Pulse Width

      Pulse Width Range

      20ns ~ 10s

      Slope Trigger

      Slope Trigger Mode

      Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope

      Slope Trigger Point

      Equal: The oscilloscope triggers when the waveform slope is equal to the   set slope.

      Not Equal: The oscilloscope triggers when the waveform slope is not   equal to the set slope.

      Less than: The oscilloscope triggers when the waveform slope is less   than the set slope.

      Greater than: The oscilloscope triggers when the waveform slope is   greater than the set slope.

      Time Range

      20ns ~ 10s

      Overtime Trigger

      Over Time Modee

      Rising edge or Falling edge

      Time Range

      20ns ~ 10s

      Alternative Trigger

      Trigger on CH1

      Internal Trigger: Edge, Pulse Width, Video, Slope

      Trigger on CH2

      Internal Trigger: Edge, Pulse Width, Video, Slope

      Trigger Frequency Counter

      Readout Resolution

      6 digits

      Accuracy (typical)

      ±30ppm (including all frequency reference errors and ±1 count errors)

      Frequency Range

      AC coupled, from 4Hz minimum to rated bandwidth

      Signal Source

      Pulse Width or Edge Trigger modes: all available trigger sources

      The Frequency Counter measures trigger source at all times, including   when the oscilloscope acquisition pauses due to changes in the run status, or   acquisition of a single shot event has completed.

      Pulse Width Trigger mode: The oscilloscope counts pulses of significant   magnitude inside the 1s measurement window that qualify as triggerable   events, such as narrow pulses in a PWM pulse train if set to < mode and   the width is set to a relatively small time.

      Edge Trigger mode: The oscilloscope counts all edges of sufficient   magnitude and correct polarity.

      Video Trigger mode: The Frequency Counter does not work.

      Measure

      Cursor Measurement

      Manual: Voltage difference between cursors: △V

      Time difference between cursors: △T

      Reciprocal of △T in Hertz (1/ΔT);

      Tracing: The valtage and time at a waveform point;

      Auto Measuerment

      Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time,   Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty,   -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS,

      Scope Trendplot

      1.2M Point

      Waveform Generator Mode

      Frenquency Range

      1Hz(DC)~25MHz

      DAC Clock

      2K~200MHz adjustable

      Memory Depth

      4KSa

      Vertical Resolution

      12 Bits

      Stability

      <30ppm

      Amplitude

      ±3.5V Max.

      Output Impedance

      50 Ω

      Output Current

      50mA Ipeak=50mA

      System Bandwidth

      25M

      Harmonic Wave Distortion

       -50dBc(1KHz),  -40dBc(10KHz)

      General Specifications

      Display Resolution

      640 horizontal by 480 vertical pixels

      Display Contrast

      Adjustable (16 gears) with the progress bar

      Frequency(typical)

      1kHz

      Dimension

      260mm*220mm* 75mm

      Weight

      2.5KG(without Packing)

    • Specification

      SHS800 Series

      DSO8000E Series

      Models

      SHS806/SHS810/SHS815/SHS820

      DSO8072E/DSO8102E/
      DSO8152E/DSO8202E

      Channels

      2

      2

      Bandwidth

      60MHz/100MHz/150MHz/200MHz

      70MHz/100MHz/150MHz/200MHz

      Real Time Sampling Rate

      SHS806/SHS810/SHS815: 
      1GSa/s(1CH), 500MSa/s(2CH)
      SHS820: 500MSa/s

      1GS/s

      Equivalent Sampling Rate

      50GSa/s

      - - - -

      Memory Length

      2Mpts:SHS806/SHS810/SHS815;
      32kpts:SHS820

      2Mpts

      Vertical Sensitivity

      2mV~100V/div

      2mV~100V/div

      Horizontal Range

      5ns~50s/div:SHS806;
      2.5ns~50s/div:SHS810/SHS815/SHS820

      4ns/div~2000s/div:DSO8072E/DSO8102E;
      2ns/div~2000s/div:DSO8152E/DSO8202E

      Display

      5.7 inch

      5.6 inch

      Data Recorder

      Signal Generator

      - - - -

      Multimeter

      Maximum Input Voltage

      AC: 750V; DC:   1000V

      AC: 600V; DC:   800V

      Maximum Input   Current

      AC: 10A;   DC: 10A

      AC: 10A;   DC: 10A

    • DSO8000E Series.pdf

      Handheld Oscilloscope.pdf

    • *From:
      Enter your email
      *Message:
      Enter your Message
Corpyright © 2011 Wellzion Electronic Technology CO.,Ltd All Rights Reserved     备案许可证号:闽ICP备12000597号
Contact us
----Tel:+86-592-5562446----
Follow Us On