Basic Function | Measurement Range | Accuracy |
DC Voltage | 400mV/4V/40V/400V/1000V | ±(0.5%+5) |
AC Voltage | 400mV/4V/40V/400V/750V | ±(0.8%+10) |
DCA | 400uA/4000uA/40mA/400mA/4A/20A | ±(1.0%+5) |
ACA | 400uA/4000uA/40mA/400mA/4A/20A | ±(1.5%+10) |
Resistance | 400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ | ±(0.8%+2) |
Capacitance | 40nF/400nF/4uF/40uF/400uF/4mF/40mF | ±(2.5%+5) |
Frequency | 10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/30MHz | ±(0.5%+4) |
Temperature | -40°C~1000°C | ±(1.0%+5) |
0°F~1832°F | ±(1.0%+5) | |
True RMS | √ | |
NCV Function | √ | |
Diode/hFE Measurement | √ | |
Backlight Display | √ | |
Duty Cycle Measurement | √ | |
Continuity Alarm | Less than 50Ω±10Ω | |
Low Battery Indication | Less than approx 2.4 V | |
Data Hold | MAX,MIN,HOLD | |
Auto Power Off | About 15 minutes later | |
Function Protection | √ | |
Input Impedance | 10MΩ | |
Sampling Rate | 3 times/seconds | |
AC Frequency Response | 40-400Hz | |
Operation Method | Auto Range | |
Max Display | 4000 counts | |
LCD Size | 65x41mm | |
Power Supply | 2×1.5AAA | |
Power Consumption | Quiescent current approx 2mA |
Color | Orange and Grey |
Weight | 290g(including battery) |
Meter size | 185×93×35mm |
Standard accessory | Test leads, battery, manual, TP01 temperature probe |
Packing | Gift box |
Standard packing per carton | 30pcs |
Carton size | 45.5×32.5×43.5cm |
Standard G.W per carton | 17kg |
*From: |
Enter your email |
*Message: |
Enter your Message |